FEATURES:
- This model is specially designed for 220V Submersible or Under Water Pump (Any HP) operating with a Electrical Panel in which there is a MCB, one Push to on Switch (Green), but no Stop Switch. Normally to Start the Pump the MCB is made on first then Push to on Switch is pressed for 1-2 second only. To stop the pump the MCB is made off.
- It senses the Water level in both of the Over Head Tank and the Reservoir.
- It Starts Pump Automatically at low level in Over Head Tank if there be sufficient water in the Reservoir.
- It Stops the Pump when Over Head Tank become full or when lower reservoir gets empty protecting the pump from dry run.
- Have over current Limiting and Short Circuit protecting ISI marked MCB.
- Pump can be operated manually at any time even when this unit is in Installation.
- Reservoir sensing can be by passed by sorting the points G 1 & 2 placed at right bottom side of this controller device.